Lithium Battery 3.7V Lithium Polymer Battery 3.2V LifePo4 Battery 1.2V Ni-MH Battery Button Coin Battery
3.7V Battery Pack 7.4V Battery Pack 11.1V Battery Pack 14.8V Battery Pack Other Battery Pack
Sino Science&Technology Battery Co.,ltd is a high-tech production enterprise which specialize in the R&D and production of Lifepo4 batteries,energy storage battery,portable UPS power supply,personalized customization lithium battery pack etc .
Environmental cylindrical 18650 21700 32700 26650 14500 18500 lithium ion rechargeable battery, LifePO4 battery,3.7V lithium polymer battery, NiMH battery , NiCD battery ,Lead acid battery,dry cell battery ,alkaline battery ,heavy duty battery, button cell battery etc. we devote to R&D,innovation ,production & sales
Shenzhen Green Power Energy Battery Co.,ltd specializes in a wide range of digital battery such as environmental cylindrical 18650 21700 32700 26650 14500 18500 lithium ion rechargeable battery, LifePO4 battery, 3.7V lithium polymer battery, NiMH battery, NiCD battery, dry cell battery, alkaline battery, heavy duty battery, button cell battery etc. we devote to R&D, innovation, production & sales. With automatic production machines we have been exported goods to all over the world over 15years. We have complete exported certificate such as KC, CE, UL, BSCI, ROHS, BIS, SGS, PSE etc
Dongguan Datapower New Energy Co.,ltd is a high-tech production enterprise which specialize in the R&D and production&sale of lithium polymer batteries,drone battery,airplane batteries &battery pack etc.
Anhui Seong-hee New Energy Technology Co.,ltd is a high-tech production enterprise which specialize in the R&D and production of primary batteries. And mainly produces and sells alkaline batteries & carbon zinc batteries. there are size AA, AAA, C, D, 9V etc
Guizhou STD Battery Co.,ltd is a high-tech production enterprise which specialize in the R&D and production & sale of lithium polymer batteries, drone battery, airplane batteries & battery pack etc.
release time:2024-01-11 Hits: Popular:AG11 battery
How to activate the battery? UPS battery maintenance solution. In UPS power supplies, maintenance-free sealed lead-acid batteries are widely used. Good maintenance and upkeep can not only ensure the safety of power supply, but also greatly extend the service life of UPS batteries. Perform routine maintenance on the UPS battery, so as to extend the life of the UPS battery and reduce the failure rate to the greatest extent.
How to activate the battery?
1. Unscrew the plastic cover of each compartment of the battery and check the internal liquid level. If it is not enough, fill it up to the normal level.
2. Use a multimeter to check the voltage of each grid to see if it is basically close and whether there is reverse polarity. Whether the total voltage is above 10.8 volts. If any individual grid is found to have low voltage or reverse polarity, it must be supplemented or the polarity corrected separately.
3. It is best to use a charger with adjustable voltage and current and a voltage and current display meter. Connect the connection cable, turn on the power, and observe the changes in voltage and current. If it reaches 14 volts and there is still no charging current, continue to increase the voltage to 16 volts and wait.
4. As long as there is current, it means activation begins. Slowly wait for the current to increase. When the current exceeds one-tenth of the capacity, for example, when the current of a 24-hour battery exceeds 2.4 amps, reduce the voltage and adjust the current to 2.4 amps. Wait until the voltage drops below 14 volts and there is still 2.4 amps of current. The activation is successful and the charging stage is entered.
5. This kind of long-term UPS battery generally needs to be charged for more than 14 hours, and the maximum charging voltage at the end of charging does not exceed 14.9 volts.
UPS battery repair method
Pulse repair method:
A better way to eliminate sulfuration in batteries is to use the pulse repair method. When repairing the battery, the instantaneous voltage of the pulse is generally between 60V and 300V according to the functional needs of the product. For example, the pulse voltage value of products used to extend the battery life is not necessarily too large. Specially for battery repair products The pulse voltage value can be too large. If the pulse voltage is high, the battery repair time will be short. If the pulse voltage is low, the battery repair time will be relatively long. Although the voltage at the pulse instant is very high, the average voltage is not high, which does no harm to the human body. It is very Safety.
Full charge and full discharge repair method:
The full charge and full discharge repair method is to fully charge the battery and then completely discharge it to repair the battery. The full charge and full discharge repair method mainly has a certain repair effect on slightly damaged batteries. At the same time, this method can also effectively activate the active substances deep in the battery and increase the battery capacity.
Hydration repair method:
The "water loss" of the battery can be repaired by replenishing water. The purpose is to dilute the sulfuric acid with increased concentration to carry out the electrolysis reaction normally. The method of replenishing water is relatively simple. Just open the battery cover and you will see six round holes. Inject a certain amount of distilled water into each hole and soak it for more than 24 hours.
UPS battery maintenance solution
The UPS battery maintenance solution consists of three parts: battery pack capacity monitoring, single UPS battery charge and discharge activation, and battery-specific intelligent protection.
1. Battery pack capacity monitoring
The float voltage, current, charge and discharge voltage, and current of the UPS battery can be monitored and recorded online. After recording the discharge data, the performance of the battery pack can be judged, lagging cells can be found, and the remaining capacity of each cell can be given.
2. Single battery charge and discharge activation
For the discovered backward single cells, charge and discharge to activate the failed active material, reduce the internal resistance, compensate for the voltage difference and supplement the remaining capacity, so as to avoid the further deterioration of the backward single cell and affect other cells, that is, perform early testing on the battery. Treatment and prevention, and timely replacement of single batteries that cannot be compensated.
3. Special intelligent protection for batteries
Special intelligent protection for lead-acid batteries is a high-tech technology that uses electronic pulse technology to perform automatic daily maintenance on lead-acid batteries in use. The protector also has the function of repairing lead-acid batteries that have failed due to shock, fatigue, or overuse due to the saltation of lead sulfate on the plates. It cleverly uses the energy of the battery itself to generate electronic pulses and feeds them back to the battery. It uses electronic methods to effectively prevent the battery from stable capacity output, improve the working efficiency of the battery, fundamentally improve the working performance of the lead-acid battery, and greatly extend the battery life. life, save money and energy, and also play a positive role in environmental protection.
These three processes work together to solve the problem of the current lack of necessary maintenance methods and tools for UPS batteries. They can not only test the battery performance for you and find backward cells, but also help you activate the backward batteries and provide early treatment to the batteries, which is effective Prevent failures from occurring.
Monitoring the UPS charging system is an important part of maintaining the UPS power system. Many users neglect the monitoring of the UPS charging system due to the lack of necessary testing methods. If the UPS charging system is broken, even if a new battery is replaced, its service life will be shortened. will become shorter. The traditional method of judging UPS battery capacity is the same as that of general batteries. The entire battery pack is separated from the communication power supply system and put on a discharge meter. It is discharged at a constant current rate of 10 hours, and then the battery pack is discharged at a constant current rate that reaches the discharge termination voltage first. The discharge time and current of the battery are used to calculate its capacity.
Read recommendations:
Battery failure.lithium battery 18650 3.7v
Last article:LR1130 battery.Portable UPS power supply solution for outdoor communication industry
Next article:CR2430 battery.220V outdoor high-power portable UPS mobile power supply solution
Popular recommendation
16340 battery maker
2023-03-22home energy storage lithium battery manufacture
2023-05-10402035 lipo battery Factory
2023-03-2218650 lithium battery
2023-03-22Nickel Hydride Batteries wholesaler
2023-03-22186095 6000mAh 7.4V
2022-08-237/AAA USB 1.5V 600mWh
2023-06-29Home energy storage battery FBC-HS01
2022-11-08Electric vehicle lithium battery GN-24100-FAP
2022-09-27LR14
2022-12-07Lithium Battery LQ-1210
2022-08-196F22
2023-03-27LR14
2023-02-07L822 32A/29A
2022-10-09Lithium-ion battery G500
2022-11-22502030 battery
2023-06-25li ion 18650 battery pack
2023-06-25703048 lipo battery
2023-06-25AAA NiMH batteries direct sales
2023-08-04LR1130 battery
2023-06-25Advantages Analysis of Polymer Lithium Batteries
2024-11-05Motor lithium battery.14250 battery
2023-05-24What are the advantages of lithium batteries?
2024-03-12What is the working principle of lead-acid battery charging and discharging?
2024-03-11Fuel cell vehicles
2024-06-18What are the advantages of industrial lithium batteries
2022-11-07Production requirements for lithium batteries.18650 lithium battery 3000mah
2023-08-11lithium ion battery cells 18650.18650 lithium-ion battery pack production process
2023-10-13The advantages of lithium iron phosphate battery.lifepo16 battery for solar energy storage Processin
2023-05-08Five advantages of lithium iron phosphate battery
2023-03-06